Apc back ups xs 1000 manual
Capacity Used Max. Please enter load to see calculated "Max. You should consider saving any work in progress. Inspection Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is. Adjustable voltage-transfer points. Warning: Electricity can severely hurt you or kill you. If you are not comfortable and compete Toggle navigation. Run time for load. Enter the total load power draw of all devices to be protected by the UPS here. Based on the value entered we will estimate the run time that you will have during a total power outage.
Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Capacity Used. The maximum percentage of UPS capacity used to support your specified load. Nominal Output Voltage V. Nominal Input Voltage V.
Cord Length 6ft 1. Maximum Input Current Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Provides notification of changing utility power and UPS power conditions. Periodic battery self-test ensures early detection of a battery that needs to be replaced. Provides early-warning fault analysis on batteries enabling timely preventive maintenance.
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment. Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
This LED informs users of potentially dangerous wiring problems in the wall circuit. Provides protection of connected equipment from power surges on the data lines. Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Maximizes battery performance, life, and reliability through intelligent, precision charging.
Text and mimic diagrams that display modes of operation, system parameters and alarms. Easy recovery from overloads; no need to replace a fuse. Connect bulky transformer block plugs without covering up other outlets.
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR. Product Distribution United States. Technical Specifications Print.
Load Crest Factor 3 : 1. Topology Line interactive. Waveform type Stepped approximation to a sinewave. Maximum Output Current Transfer Time 8 ms typical : 12 ms maximum. Input voltage range for main operations 88 - V. Number of Power Cords 1. Battery type Lead-acid battery. Typical recharge time 16hour s. Expected Battery Life years 3 - 5. RBC Quantity 1.